Data Center tam zawkin eng Cooling Method nge an hman?

Jun 22, 2026

Message pakhat dah la .

Data Center tam zawkin eng Cooling Method nge an hman?

Data center te hi digital economy dinna bulpui ber a ni a, cooling system te hi an "nunna kawng" a ni. International Energy Agency (IEA) chhinchhiah danin, tunah hian khawvel puma electric hman zat aṭanga 1% vel chu data center-te a ni a, cooling system chauh hian chu total-3 aṭanga 30% aṭanga 40% vel a ni. Chuti a nih chuan data center tam zawk hian eng cooling method nge an hman tak tak? A chhanna chu:air cooling hi mainstream a la ni reng a, liquid cooling pawh a sang chho chak hle a, he transition chhung hian hybrid cooling hi a awm fo tawh bawk.

I. Air Cooling: A la ni reng a, Absolute Dominant Force a ni

Air cooling hi cooling method hmanlai leh puitling ber a ni a, fan, heat sink, leh airflow circulation hmangin processor leh memory ang chi component pawimawh tak tak te chu cooling a ni. Uptime Institute-in kum 2025-a Global Data Center Survey a neih aṭanga a lan dan chuan,data center 70% chuang chuan an cooling method ber atan air cooling an la ring tlat a ni. Survey dang pakhatah chuan 45% chuan an primary data center-ah fully air-cooled system an hmang tih an sawi.

Hun rei tak chhunga air cooling-in a thunun chhan chu a chiang hle:cost-effectiveness, enkawl awlsam, leh technology lama puitlin theihna. Traditional data center rack power density 10kW leh 15kW inkar tan chuan air cooling hi a tawk vek a ni. Data center tenau leh lian-sized leh traditional enterprise server room-ah chuan air cooling hi absolute mainstream a la ni reng a ni.

Mahse, air cooling-a tihkhawtlai theihna chu a langsar chho zel a ni. Single-rack power chu 30kW aia tam a nih chuan traditional air cooling-a Coefficient of Performance (COP) chu 1.5- hnuaiah a tlahniam a ni. AI computing power hmanga high-density deployment hmachhawn hian air cooling hian a physical limit a hnaih tawh hle.

Oasis Bingfeng Closed-Circuit Cooling Tower

II. Liquid Cooling: A chak ber-Thiltihtheihna thar" a lo thang chak ber.

Liquid cooling technology pawh a lo thang chak hle a, acompound annual growth rate chu 20% vel a ni.. Tunah hian liquid cooling hi chi thum-ah a inthen ber a:cold plate liquid cooling, single-phase immersion cooling, leh two{1}}phase immersion cooling te a ni-.

Cold plate tui lum a nitunah hian liquid cooling method hmanlai ber a ni. Chip surface-a metal cold plate dah hian coolant chu cold plate chhungah a kal kual a, lumna a phur chhuak a, single-rack cooling capacity chu 75kW- thleng a ni. Single-rack power 10kW-ah chuan liquid cooling solutions neitu nihna senso zawng zawng hian air cooling man a pel tawh a ni.

Immersion liquid hmanga tihlum a niserver-te chu dielectric cooling fluid-ah direct-in a thun a, cooling efficiency sang ber a pe a ni. Immersion liquid cooling hian Power Usage Effectiveness (PUE) chu 1.03 ah a tihhniam thei a, air cooling-. Immersion cooling hian kum 2026 leh 2028 inkar hian nasa takin a pung dawn niin an sawi.

Tunah hian data center 42% chuan "air + liquid" hybrid cooling approach an hmang tawh a, kum 2024 khan 38% an hmang tawh a ni.

Oasis Bingfeng Evaporative Condenser

III.Circuit Cooling Tower te kha khar a ni: Liquid Cooling Systems hnung lama Unsung Hero

Liquid cooling system te hnathawh thatna chu pawn lam heat rejection stage - atanga support a innghat a, hei hi a nikhar-circuit cooling tower te a awm hmun pawimawh tak an chang.

Liquid cooling system hian chip atanga lumna chu cold plate hmangin coolant ah a transfer thin. Chumi hnuah chuan heated coolant chu external heat exchange equipment-ah a lum theih nan thawn a ngai a, chutah chuan server-ah recirculate leh a ngai a ni-.Circuit cooling tower khar tawh-hi he pawn lam heat exchange stage-a hmanraw bulpui ber pakhat an ni. Fully enclosed circulation design hmangin closed-circuit cooling tower-a tui chu boruak nena direct-a inzawm lovin sealed coil chhungah a kal a, hei hian tui thianghlim quality leh scaling laka a do theihna a tichiang a ni. Heng mizia te hian a siamkhar-circuit cooling tower te a awmliquid cooling system-a cooling support nghet leh rintlak tak pekna atan a tha hle. Liquid cooling hmanga data center-te tan chuan, .khar-circuit cooling tower te a awmheat rejection tha tak neih theihna tur leh long-term system stability neih theihna tura hmanraw pawimawh tak an ni.

Oasis Bingfeng Evaporative Condenser

IV. The Trend: Air Cooling hian a thunun a, Liquid Cooling a ti chak a, Hybrid hi Norm a ni

Tuna data center cooling kalphung tlangpui chu:air cooling hian share lian ber a la nei a, liquid cooling hian rang takin a rawn lut a, he transition chhung hian hybrid cooling hi mainstream choice a ni ta a ni-. Data center thar sakna atan chuan cold plate liquid cooling hian air cooling a thlak zauh zauh a, primary cooling technology-. Kum 2030 hmalam thlir chuan liquid cooling hi model lian ber a nih beisei a ni a, cooling capacity zawng zawng atanga 61% vel a ni tura chhut a ni.

Data center cooling hi "air cooling-dominated" atanga "liquid cooling-dominated" ah a inthlak mek a ni. Liquid cooling system-a heat rejection component pawimawh tak a nih angin, closed-circuit cooling tower-te hian he inthlak danglamnaah hian hmun pawimawh tak an chang chho zel a ni.