Common Faults leh Closed Cooling Towers-a chinfel dan tur .
Sep 17, 2025
Message pakhat dah la .
Closed Cooling Towers chu tui a vawt laiin lumna absorb a nih thu principle hmangin cooled liquid chu a ti lum thei a ni. Closed cooling tower-a circulating medium chu closed circulation-ah a awm avangin, circulating medium chu a bawlhhlawh lo tih a tichiang thei a, chu chuan hmanraw lian tham tak takte hnathawh dan tha tak a humhim a, hmanrua ber service life pawh a ti rei thei a ni. Mahse, hun rei tak chhunga hman tur eng pawh chu harsatna hrang hrang a thlen awlsam hle. Closed cooling towers, as large-scale equipment pawh hian kum engemaw zat hman a nih hnuah harsatna engemaw zat a nei thei bawk. Tunah chuan Oasis Ice Peak Fluid Equipment Co., Ltd. chuan closed cooling tower chungchanga harsatna awm thei te an sawi dawn a ni.
1. Closed cooling tower-a fault awm tlangpui: Fan harsatna .
Air volume a tlem chuan fan blades angle dik taka siamrem leh belt siamrem ang chi method te pawh hman theih a ni. Mahse, fan blade a chhiat chuan a thlakna tur kawng dang a awm lo. Tin, blade pakhat a chhiat chuan blade set pumpui chu thlak a ngai a ni. Dik tak chuan fan-te harsatna tam tak a awm a, chu chu blade leh air cylinder inkara inhnawh tawnna, blade-te vibration, etc. te hi a ni a, chu chu a hmuna test ngai a ni.
2. Closed cooling tower-a fault awm fo: Motor harsatna .
Motor problem hi a awlsam a, motor quality nena inzawm, heating, burning out, vibration, etc. tih loh chu engmah a awm lo a, vibration hi bearing wear nen a inzawm thei bawk. Closed cooling tower-a motor te hi a tlangpuiin a bik taka siam chhuah outdoor motor an ni a, chu chuan motor damage rate chu high-temperature, high-humidity leh high{{4} intensity environment-ah a tihtlem a ni. Harsatna bikte chu chiang taka zirchian a ngai a, a tam zawk chu siamthat emaw thlak emaw hmangin chinfel theih a ni.
3. Closed cooling tower-a fault awm tlangpui: Tui khawltu tihchhiatna .
A tlangpuiin, kum tam tak chhunga hman tawh cooling tower-te chuan tui khawl chhia chungchangah harsatna an nei ang. Tui khawl chhia chuan tui mist a tlakbuak ang a, tui drift rate pawh nasa takin a tisang ang. Tui a tichhe mai ni lovin, bacteria te chu thawkna kawngah an inhnim a awlsam a, natna hrik a lo chhuak a ni. Closed cooling tower-a tui khawltu service life chu a tlangpuiin kum 8-10 vel a ni a, a zawng zawng hi raw material hmanga siam vek a ni a, chuvangin a chunga harsatna awmte hi a tlem hle. A chunga harsatna kan tawhte hi a tlangpuiin tui khawl hmasa ber siamthat kan tum tlangpui a, a chhe tak tak leh thlak ngai te chauh thlak leh mai tur a ni.
4. Closed cooling tower-a fault awm tlangpui: Tui semna pipe harsatna .
Cooling tower-a tui distribution pipe te hi deformation, blockage, corrosion leh perforation te bending an ni tlangpui. A tlangpuiin heng harsatnate hi siamthat theih a ni lo va, a hmun thar chauh pawh thlak theih a ni.
5. Closed cooling tower-a fault awm fo: Nozzle-a harsatna awmte
Nozzle hi thil chhe thenkhatin a block fo thin. Anni chu iron wire hmanga bawlhhlawh paihin unblock theih an ni. Nozzle te chu a chhe emaw, a chhe emaw a nih chuan a hnathawh dan dik lo a nih chuan thlak a ngai a ni.
6. Closed cooling tower-a fault awm fo: Filler harsatna .
Filler-a harsatna awm fo chu scaling leh aging te a ni. Cooling tower khar hian suspended fillers a hmang a, manual high-pressure water washing hmangin scaling pawh a paih thei a, hei hian counter-flow tower-a fillers tihfai harsa tak buaina chu a chinfel sak a ni. Raw fillers hman a nih chuan service life hi kum 10 aia tam a ni a, hun rei lote chhungin tarna a thleng dawn lo. Aged fillers thlak a ngai a, fillers te chu scaling emaw sludge tam lutuk emaw hmanga tihfai nan ngaihtuah theih a ni.
7. Closed cooling tower-a fault awm fo: coil problems .
Closed cooling tower coil te chu kum engemaw zat hman hnuah perforated a ni ang a, a nih loh leh a chung lam chu scale a ni ang. Scaling na tak nei coil te chuan a lumna a ti bo thei dawn lo. Coil leak tan chuan siamthat theih a ni lo va, thlak theih chauh a ni. Surface scaling na tak nei coil te tan chuan tihfai emaw, enkawlna tha tak emaw ngaihtuah theih a ni. Scaling na tak tak nei coil te chu thlak theih chauh a ni. A tlangpuiin, thla 3-5 danah vawi khat maintenance hian scaling na tak a pumpelh thei a, cooling tower service life nasa takin a ti rei thei bawk.
8. Enkawlna leh enkawl dan .
1) Spray system enkawl dan .
Cooling tower hnuai lama tui tank chu tui thianghlim, a tha ber chu tui thianghlim a tha tur a ni a, pH value chu 6 leh 8 inkar a nih theih nan enfiah tur a ni
Tuikhuah chu kar khatah vawi khat tal silfai tur a ni a, chu chuan tuikhuah chu a paih chhuak ang a, tui a khawlkhawm chu a thlak leh ang;
Spray tui dinhmun enfiah fo thin ang che. Thil dik lo a awm chuan pipeline leh nozzle te chu block a nih leh nih loh enfiah la;
2) Anti-heat exchanger (suggestion) freezing (suggestion) .
Ambient temperature chu 0℃aia hniam a nih chuan cooling tower coil-a tui awmsa chu a khar hnuah a vawt ang a, chu chuan coil chu a ti chhe ang. Low-temperature winter-ah chuan rei tak hman loh chuan boruak nen a vawt tur a ni. Circulation system-a tui tank tan chuan install lai hian tui tank chhunga liquid medium liquid level chu a khar hunah heat exchanger aiin a hniam zawk tur a ni.
Thlasik laiin i khar dawnin [Anti-Freeze/Normal] chu [anti-freeze] position-ah dah rawh. Timer controller parameters setting hmang hian system tui circulate chu a circulate fo thei a ni.
Anti-freezing purpose tihhlawhtlinna tur hian hmalakna hrang hrang siam theih a ni:
A siam chhuah laiin measures .
.
2 Tui khawlna tha tak nei tui collector hmang la, chutiang chuan tui tla te te pawh a float chhuak lo ang a, a freeze lo ang.
3 Fans i lei dawnin fans te hian deicing atana backup measure atan hun rei lo te chhung reverse an nei thei tih ngaihtuah la.
4 Nozzle ruahmanna design ngaihtuah a ni tawh. A chhehvel nozzle leh tower wall inkar hlat zawng chu a lian zawk a, a chhehvel nozzle diameter chu wall flow tihtlem nan a chhung lam aiin a lian zawk 2 a ni.
Tui lum spraying .
Inner circulation liquid pipe-a liquid temperature chu 8℃aia hniam a nih chuan, hot water spraying system chu automatic-in a intan ang a, heat exchanger coil pumpuiah tui lum a spray ang a, pipe chhunga liquid leh temperature chu a lum ang a, coil chu freeze-in a chhe lo ang
Tui lum siam chhuah dan .
Spray water tank-ah hian electric heater dah a ni a. Automatic gear-a dah a nih chuan electric heater chu spray water tank-a tui lumna chu℃5 aia tlem emaw, a tlukpui emaw a nih chuan automatic-in a intan ang a, spray tui chu a lum ang a, a lumna chu℃10 a thlen chuan a tawp nghal ang. Liquid level switch a nei bawk. Liquid level chu set position aia hniam a nih chuan electric heating system chu a lock nghal vek ang.
Organizational measures 1.1.
rel khalhtute an ni. A temperature tlem ber chu 5℃aia hniam a nih chuan, operation tihtawp hunah, a hun taka system chhunga tui awm zawng zawng chu a hun taka paih vek a, freezing leh cracking hlauhawmna awm lo turin.
Technical lama hmalakna tur .
Internal liquid zawng zawng chu local temperature atana hman tur antifreeze hmangin thlak la, chutiang chuan vawi khat atan freezing a awm dawn lo va, production, rest emaw maintenance-ah pawh i inring thei ang.
3) A hnuah attenuation .
Cooling capacity hi a tawpah chuan parameter hrang hrang, heat exchange area, ventilation speed, leh heat transfer coefficient te ah a innghat a ni. Operation chhung hian stainless steel pipe chhungah hian scaling a awm dawn lo. Mahse, pawn lam atanga spray cooling atan tap tui pangngai hman a nih avangin, spray tui a lo chhuah zel avangin, tui chhunga ca2+ leh mg2+ ang chi scaling ion concentration chu a sang chho zel a, chu chuan stainless steel pipe pawn lam wall-ah scale a siam ang a, heat transfer coefficient a tihtlem bakah cooling capacity a nghawng ang. Chuvangin, kan company-a equipment product manual chuan management lamah chuan post staff-te chuan spray water chu an paih chhuak tur a ni tih a sawi uar a, kar tin tui thar hmanga thlak a ngai a, chu chuan scaling ion concentration a tihtlem a ngai a ni Tin, closed cooling tower-a spray water tank-ah hian spray langsar tak a awm a, chu chu scaling tihtlem nan kar tin thlak emaw, tihfai emaw ngaih pawimawh a ni.
4) Thil hmanrua enkawl dan .
Thil hmanrua hman lai hian hmanrua awm reng chuan enkawl a ngai a, hmanrua hman dan tur pawh enkawl leh thlak danglam a ngai bawk. Closed cooling tower-a operating equipment-ah hian fans, water pump, leh electrical components te a awm a ni. Fans te hi cooling tower-a fans bik an ni a, efficiency sang tak, power hman tlem, noise hniam, leh air volume lian tak tak an nei a; Spray water pump te hi special pump a ni a, lift hniam leh flow lian tak nei a ni a, hei hian flow rate a ti sang a, power hman a ti tlem a, hmanrua service life a ti rei bawk.
Users’ maintenance awlsam zawk nan kan company hian unified models a hmang a, chutiang chuan users te chuan spare parts inventory an tihtlem thei a, maintenance an ti awlsam thei a, maintenance chu standardized zawka siam theih a ni bawk.
Inquiry thawn rawh .