Composite Cross Type khar a ni a, a khar theih bawk.
Evaporation: 0.07-2.60 vel a ni.
Type classification: Double-side air intake leh single-side air intake composite flow
Air intake awmna hmun: Tower wall side air intake .
Media thianghlimna:, a pum puia khar 100% pure .
Thil siamchhuahna hmanrua: High-CNC siam chhuahna hmanrua chiang tak
Anti-Condensation Design: Special Coil Technology, Temperature hniam tak hi condensation awlsam a ni lo
Air flow siamthatna: Multi-Air speed option hrang hrang grade, cooling mamawh hrang hrang nena inmil. Airflow hi adjustable a ni: cooling mamawh hrang hrang nena inmil turin air speed tam tak thlan theih a ni.
Installation slope: Reserved slope hnuai lam, tui chhuah awlsam leh tui pung tur venna.Temperature Resistance of Materials: Components te hi temperature sang leh hniam lakah an inveng thei a, temperature inthlak danglamna nasa tak an tawk thei bawk.
Remote operation leh enkawl dan: Online diagnosis thlawp, ON-site maintenance tihtlem.
Seismic performance: Structure hi lirnghing dona atana siam a ni a, multi-seismic area atan a tha hle.
Products sawifiahna .
Composite Cross Type Closed Cooling Tower hi temperature sang tak fluid emaw project temperature danglamna lian tak nei project emaw tihlumna atan a tha a, composite cross type closed cooling towe hian energy hman tamna leh size lian tak a nei a ni. Composite Cross type closed cooling tower-a maintenance hniam, mixed flow design hi market-a closed cooling tower tha zawk zinga mi a ni.
Composite Cross Type Closed Cooling Tower chuan process refrigerant chu circuit fai tak, fully enclosed, contamination laka venhim a ni a, chutih laiin composite cross type closed cooling towe chuan cooling tower leh heat exchanger hnathawh chu unit khatah a dah khawm a, operation leh maintenance performance tha tak a pe a ni.

Cross-Flow emaw Composite Cross Type Closed Cooling Tower chu temperature sang tak awmna hmunah thlan a tha a, general area hrang hrang tan counter-flow closed cooling tower thlan a tha bawk.

Transformer leh Power Electronic Equipment Cooling Transformer in transmission process electromagnetic loss vangin heat, composite cross type closed cooling tower hmangin circulating water system hmangin cooling stable tak a pe thei a, chu chuan insulation material tar emaw, chhe emaw a awm theih avangin composite cross type closed cooling towe a veng thei a ni. Water circulation system hian composite cross type closed cooling towe chu insulation material tar emaw, tihchhiat emaw a nih loh nan stable cooling a pe a ni. Chutih rual chuan, high-frequency operation of power electronic equipment (eg inverter leh rectifiers) te hian heat an siam chhuah pawh hian composite cross type closed cooling tower hmanga temperature control dik tak a mamawh bawk.