lusTawng
Composite Cross Type khar a ni a, a khar theih bawk.

Composite Cross Type khar a ni a, a khar theih bawk.

A rilru a buai em em a, a rilru a hah em em bawk a, a rilru a buai em em bawk.
Evaporation: 0.07-2.60 vel a ni.
Type classification: Double-side air intake leh single-side air intake composite flow
Air intake awmna hmun: Tower wall side air intake .
Media thianghlimna:, a pum puia khar 100% pure .
Thil siamchhuahna hmanrua: High-CNC siam chhuahna hmanrua chiang tak
Anti-Condensation Design: Special Coil Technology, Temperature hniam tak hi condensation awlsam a ni lo
Air flow siamthatna: Multi-Air speed option hrang hrang grade, cooling mamawh hrang hrang nena inmil. Airflow hi adjustable a ni: cooling mamawh hrang hrang nena inmil turin air speed tam tak thlan theih a ni.
Installation slope: Reserved slope hnuai lam, tui chhuah awlsam leh tui pung tur venna.Temperature Resistance of Materials: Components te hi temperature sang leh hniam lakah an inveng thei a, temperature inthlak danglamna nasa tak an tawk thei bawk.
Remote operation leh enkawl dan: Online diagnosis thlawp, ON-site maintenance tihtlem.
Seismic performance: Structure hi lirnghing dona atana siam a ni a, multi-seismic area atan a tha hle.
Inquiry thawn rawh .

Products sawifiahna .

 

Composite Cross Type Closed Cooling Tower hi temperature sang tak fluid emaw project temperature danglamna lian tak nei project emaw tihlumna atan a tha a, composite cross type closed cooling towe hian energy hman tamna leh size lian tak a nei a ni. Composite Cross type closed cooling tower-a maintenance hniam, mixed flow design hi market-a closed cooling tower tha zawk zinga mi a ni.

 

Composite Cross Type Closed Cooling Tower chuan process refrigerant chu circuit fai tak, fully enclosed, contamination laka venhim a ni a, chutih laiin composite cross type closed cooling towe chuan cooling tower leh heat exchanger hnathawh chu unit khatah a dah khawm a, operation leh maintenance performance tha tak a pe a ni.

 

Closed-Circuit Cooling Tower Manufacturing Facility

 

Cross-Flow emaw Composite Cross Type Closed Cooling Tower chu temperature sang tak awmna hmunah thlan a tha a, general area hrang hrang tan counter-flow closed cooling tower thlan a tha bawk.

 

Customer Site Installation of Closed-Circuit Cooling Tower

 

Transformer leh Power Electronic Equipment Cooling Transformer in transmission process electromagnetic loss vangin heat, composite cross type closed cooling tower hmangin circulating water system hmangin cooling stable tak a pe thei a, chu chuan insulation material tar emaw, chhe emaw a awm theih avangin composite cross type closed cooling towe a veng thei a ni. Water circulation system hian composite cross type closed cooling towe chu insulation material tar emaw, tihchhiat emaw a nih loh nan stable cooling a pe a ni. Chutih rual chuan, high-frequency operation of power electronic equipment (eg inverter leh rectifiers) te hian heat an siam chhuah pawh hian composite cross type closed cooling tower hmanga temperature control dik tak a mamawh bawk.

 

hot tags .: A rilru a buai em em a, a rilru a hah em em bawk a, a rilru a buai em em bawk a, a rilru a hah em em bawk a.

Inquiry thawn rawh .